The significance of 4D CT simulation inprecise definition of target volumen lung carcinoma intensity modulated radiation therapy treatment

Slavica Marić ,
Slavica Marić
Ljiljana Tadić-Latinović ,
Ljiljana Tadić-Latinović
Branislava Jakovljević ,
Branislava Jakovljević
Pavle Banović ,
Pavle Banović
Aleksandar Kostovski ,
Aleksandar Kostovski
Milomir Milaković ,
Milomir Milaković
Dražen Jaroš
Dražen Jaroš

Published: 01.12.2016.

Biochemistry

Volume 33, Issue 3 (2017)

pp. 1487-1493;

https://doi.org/10.5937/matmed1701487m

Abstract

Implementation of IMRT with 4DCT simulation offers possibility to correlate the respiratory movements and position of tumor volume during radiotherapy treatment. The aim of this study is to quantify movements of primary tumor during IMRT treatment in three axes-Z-superoinferiorSI, X-mediolateral ML, Y -anteroposterior AP.This study included 15 patients with lung carcinomareferred to radical radiotherapy. Contouring of GTV was done in the phases FB- GTV FB, phase 0-GTV0, phase 50- GTV 50, and phase MIP-GTV MIP. Comparison was done with GTV FB as basic value. Evaluation was done in three axis-SI, AP, ML. The movements of GTV in relation to X axis were in the range 0.02-0.47 cm, in relation to Y axis in the range from 0.01-0.56 cm, and according to the Z axis in the range of 0.00-0.79 cm. Based on the results of t-test there was a statistically significant difference (p<0.05) related to X axis between the upper and lower lobe. There was no statistically significant difference (p>0.05) between the upper, lower and middle lobes related to Y and Z axis. The test results which were obtained after the 4D CT simulation and planning of IMRT treatment show the importance of high-quality and precise radiation therapy treatment.

Keywords

References

1.
Aupérin A, Le Péchoux C, Rolland E, Curran WJ, Furuse K, Fournel P, et al. Meta-Analysis of Concomitant Versus Sequential Radiochemotherapy in Locally Advanced Non–Small-Cell Lung Cancer. Journal of Clinical Oncology. 2010;28(13):2181–90.
2.
Machtay M, Paulus R, Moughan J, Komaki R, Bradley J effrey, Choy H, et al. Defining Local-Regional Control and Its Importance in Locally Advanced Non-small Cell Lung Carcinoma. Journal of Thoracic Oncology. 2012;7(4):716–22.
3.
De Ruysscher D, Faivre-Finn C, Nestle U, Hurkmans CW, Le Péchoux C, Price A, et al. European Organisation for Research and Treatment of Cancer Recommendations for Planning and Delivery of High-Dose, High-Precision Radiotherapy for Lung Cancer. Journal of Clinical Oncology. 2010;28(36):5301–10.
4.
Chan C, Lang S, Rowbottom C, Guckenberger M, Faivre-Finn C. Intensity-Modulated Radiotherapy for Lung Cancer: Current Status and Future Developments. Journal of Thoracic Oncology. 2014;9(11):1598–608.
5.
Chang JY. Intensity-Modulated Radiotherapy, Not 3 Dimensional Conformal, Is the Preferred Technique for Treating Locally Advanced Lung Cancer. Seminars in Radiation Oncology. 2015;25(2):110–6.
6.
Pan T, Lee TY, Rietzel E, Chen GTY. 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Medical Physics. 2004;31(2):333–40.
7.
Low DA, Nystrom M, Kalinin E, Parikh P, Dempsey JF, Bradley JD, et al. A method for the reconstruction of four‐dimensional synchronized CT scans acquired during free breathing. Medical Physics. 2003;30(6):1254–63.
8.
Maxim PG, Loo BW, Shirazi H, Thorndyke B, Luxton G, Le QT. Quantification of Motion of Different Thoracic Locations Using Four-Dimensional Computed Tomography: Implications for Radiotherapy Planning. International Journal of Radiation Oncology*Biology*Physics. 2007;69(5):1395–401.
9.
Radiation Units IC, Prescribing M. Recording and reporting photon beam intensity modulated radiation therapy. 2010.
10.
Sura S, Gupta V, Yorke E, Jackson A, Amols H, Rosenzweig KE. Intensity-modulated radiation therapy (IMRT) for inoperable non-small cell lung cancer: The Memorial Sloan-Kettering Cancer Center (MSKCC) experience. Radiotherapy and Oncology. 2008;87(1):17–23.
11.
Pantarotto JR, Piet AHM, Vincent A, van Sörnsen de Koste JR, Senan S. Motion Analysis of 100 Mediastinal Lymph Nodes: Potential Pitfalls in Treatment Planning and Adaptive Strategies. International Journal of Radiation Oncology*Biology*Physics. 2009;74(4):1092–9.
12.
Ahmed N, Venkataraman S, Johnson K, Sutherland K, Loewen SK. Does Motion Assessment With 4-Dimensional Computed Tomographic Imaging for Non–Small Cell Lung Cancer Radiotherapy Improve Target Volume Coverage? Clinical Medicine Insights: Oncology. 2017;11.
13.
Rietzel E, Liu AK, Doppke KP, Wolfgang JA, Chen AB, Chen GTY, et al. Design of 4D treatment planning target volumes. International Journal of Radiation Oncology*Biology*Physics. 2006;66(1):287–95.
14.
Ueki N, Matsuo Y, Nakamura M, Mukumoto N, Iizuka Y, Miyabe Y, et al. Intra- and interfractional variations in geometric arrangement between lung tumours and implanted markers. Radiotherapy and Oncology. 2014;110(3):523–8.
15.
Liu HH, Balter P, Tutt T, Choi B, Zhang J, Wang C, et al. Assessing Respiration-Induced Tumor Motion and Internal Target Volume Using Four-Dimensional Computed Tomography for Radiotherapy of Lung Cancer. International Journal of Radiation Oncology*Biology*Physics. 2007;68(2):531–40.

Citation

Copyright

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. 

Article metrics

Google scholar: See link

The statements, opinions and data contained in the journal are solely those of the individual authors and contributors and not of the publisher and the editor(s). We stay neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Most read articles

Partners